 130 kV NEW MICROFOCUS X-RAY SOURCE
L6622-01
FEATURES
G Focal Spot Size: 10 m G Easy Handling
Providing 10 m focal spot size, for the sealed-off type X-ray source with built-in power supply. It gives a clear clairvoyance image despite higher magnification ratio. Convenient handling (with no high voltage wiring) since the air cooled X-ray source and the high voltage power supply are in one package. It allows continuous maximum output, 130 kV and 300 A, operation (Large focal spot operation).
APPLICATIONS
G X-ray Non-destructive Test
* Printed Circuits * Semiconductor Devices * Soldered Parts * Combinated Materials * New Materials * Electronic Components * Ceramics * Rubbers * Plastics * Die casting
G Continuous Operation
G Built-in External Control Function
It is automatically operable from external control since it has a built-in RS-232C interface.
G Multilayer Printed Circuit Board X-ray Inspection*Drilling Instrument G Industrial On-line Process Control and Measurement G Industrial X-ray Computer Tomography System
SPECIFICATIONS
GGENERAL
Parameter Target Voltage Target Currenta Maximum Output Power Focal Spot Size Small Focal Spot Large Focal Spot Small Focal Spot Large Focal Spot Small Focal Spot Large Focal Spot 40 to 100 kV 100 to 130 kV Value/Description 20 to 130 0 to 250b 0 to 100 0 to 300 13 39 10 40 43 18 3 Continuous Unit kV A A A W W m m degree mm mSv/h Max. --
Beam Angle Minimum Distance Focus / Object Environmental X-ray Dose Leakage Operation
NOTE: a Refer to Figure 1 b In the range of output (= Tube voltage x Tube current) less than 10 W
IX-RAY TUBE UNIT
Parameter X-ray Tube Cooling Method Window Material Target Material Cathode Material Window Position High Voltage Power Supply Operation / Storage Temperature Operation / Storage Humidity Weight Description Sealed Type Forced Air Cooling Beryllium (200 mt) Tungsten Dispenser Cathode End-window Built-in Type +10 to +40 C / 0 to +50 C 85 % RH Max.a Approx. 12.5 kg
IX-RAY CONTROL UNIT
Parameter Function Protection External Control Operation / Storage Temperature Operation / Storage Humidity Power Consumption Inter Voltage Installation Method Weight Description Target Voltage/Current Pre-set, Auto Warm-up Safety Interlock RS-232C 0 to +40 C 85 % RH Max.a 200 W Max. 24 V dc Designed for both bench-top and rack mounting Approx. 6 kg
NOTE: a Without moisture condensation.
Figure 1: X-ray Tube Operational Range
350 300 LARGE FOCAL SPOT
TLSOB0046EB
TARGET CURRENT (A)
250 200
150 100
SMALL FOCAL SPOT
50 0 0 20 40 60 80 100 120 140
TARGET VOLTAGE (kV)
130 KV MICROFOCUS X-RAY SOURCE
DIMENSIONAL OUTLINE (Unit: mm)
X-RAY TUBE UNIT
X-RAY UNIT INSTALLATION SCREW HOLE 4-M6 D8 18 20 1 X-RAY WINDOW 55 1
43
AIR VENT FOCAL SPOT 175.0 0.5
BEAM ANGLE 248 2
TLSOA0046EB TLSOA0047ED
15
90.0 0.5 110 2
11 1 100 MIN.
CONTROL CABLE RECEPTACLE 300 2 X-RAY UNIT INSTALLATION SCREW HOLES 4-M6 D8
15
175.0 0.5
X-RAY CONTROL UNIT
100 MIN. FRONT VIEW
VOLTAGE X-RAY MODE
X-RAY OFF
SIDE VIEW
X-RAY 130 CONTROL UNIT
OVER ERROR
CURRENT
STANDBY
CONTROL
AGING ON INTER LOCK PRE-SET
CONTROL
PRE-SET
OPERATE
ON OFF REMOTE
SPOT SIZE
LARGE
12
9
426 2 482 2
50
kV
A
99 2
9
40
90.0 0.5
300 2
30
INTERCONNECTION CABLE CONNECTOR DIA 33 mm MAX.
REAR VIEW
X-RAY REMOTE
AGING SIGNAL
T 6.3A 250V
INTER LOCK1
INTER LOCK2
OUTPUT
24V
RS-232
I D E N T I F I C AT I O N P L AT E
LABEL
195 2
130 KV MICROFOCUS X-RAY SOURCE
RELATED PRODUCTS
X-RAY IMAGE INTENSIFIER CAMERA UNIT C7716, C7716-10
The C7716 series X-ray image intensifier (I. I.) camera unit now offers greatly improved X-ray detection efficiency even at low energy levels. This improvement stems primarily from a built-in X-ray image intensifier having an extremely thin aluminum input window. Its thickness is only 0.3mm or less, virtually at the limit of present technology providing excellent X-ray transmit-tance and low scattering. The results are sharp, clear, high-quality images taken at low energy X-ray levels down to several keV which penetrate plastic (PET) materials.
X-RAY IMAGE INTENSIFIER CAMERA UNIT C7876, C7876-10
The C7876 is an X-ray image intensifier camera unit ideal for non-destructive inspection of light-element materials and radiation imaging at low-energy X-ray levels. The C7876 remarkably improves X-ray transmittance at low-energy X-ray levels by using a beryllium window instead of the aluminum window currently used for most X-ray image intensifiers. The result is a sharp and clear, high-contrast image taken in real time even at low energy X-ray levels down to a few keV.
! PRE-CAUTION TO USE
1. X-ray emitted from this device is harmful for human body. And it should be necessary for the operator to protect himself/herself from it. 2. During an operation, the X-ray tube unit should be installed in the X-ray shielded cabinet in order to avoid any X-ray leakage. Also the safety interlock system in X-ray control unit should be always used in order to avoid any misoperation.
# WARRANTY PERIOD
This device is guaranteed for one and a half years from data of purchase or 5000 hours of operation, whichever comes first. The warranty extends only to replacement of the products. The warranty does not cover damage due to misuse or natural calamity.
*
This product(s) conforms to the EMC directive (89/336/EEC) of the European Union.
* To meet FDA standards, the Interlock-1 circuit incorporates a relay that shuts off the X-ray generation power supply circuit if the circuit is open.
Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with our sales office. Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. (c)2001 Hamamatsu Photonics K.K
HOMEPAGE URL http://www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Electron Tube Center 314-5, Shimokanzo, Toyooka-village, Iwata-gun, Shizuoka-ken, 438-0193, Japan, Telephone: (81)539/62-5248, Fax: (81)539/62-2205
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P. O. Box 6910, Bridgewater. N.J. 08807-0910, U.S.A., Telephone: (1)908-231-0960, Fax: (1)908-231-1218 E-mail: usa@hamamatsu.com Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658 E-mail: info@hamamatsu.de France: Hamamatsu Photonics France S.A.R.L.: 8, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10 E-mail: infos@hamamatsu.fr United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road Welwyn Garden City Hertfordshire AL7 1BW, United Kingdom, Telephone: 44-(0)1707-294888, Fax: 44(0)1707-325777 E-mail: info@hamamatsu.co.uk North Europe: Hamamatsu Photonics Norden AB: Smidesvagen 12, SE-171-41 SOLNA, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01 E-mail: info@hamamatsu.se TLSO1024E04 Italy: Hamamatsu Photonics Italia: S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741 E-mail: info@hamamatsu.it
JAN. 2002 IP Printed in Japan (500)


▲Up To Search▲   

 
Price & Availability of L6622-01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X